Insertion Ultrasonic Flow Meter
- Accuracy:≤1%
- Size:DN50-DN6000 mm
- Medium Temperature:-40℃~160 ℃
- Velocity:0~ ±12 m/s
- Power Supply:DC8-36V or AC85-264V
V-method installation is the moswidely used mode for daily measurement with pipe inner diameters ranging from 15 millimeter to 200 millimeter. It is also called reflective mode or method.
Z-method is commonly used when the pipe diameter is between 300 millimeters and 500 millimeters.
W-method is usually used on plastic pipes with a diameter from 15 millimeters to 100 millimeters
Item | Parameter | |
Transmitter | Principle | Ultrasonic transit-time principle, four-byte IEEE754 floating-point arithmetic |
Accuracy | Better than ±1% | |
Display | LCD display with Chinese, English Display | |
Output | One 4-20mA Current output, Impedance0-1K,Accuracy 0.1% | |
One OCT Pulse output(Width 6-1000ms,Default 200ms) | ||
One relays output | ||
Input | Three 4-20mA Current input,accuracy 0.1%,can collect temperature, pressure,level signals etc. |
|
Connect with three-wire PT100 Plastnium resistance to measure heat flow. | ||
Data Interface | Isolated RS485 interface, can upgrade flowmeter through PC,support modbus | |
Special Cable | Twisted-pair, ≤ 50m | |
Pipe | Material | Steel,Stainless steel,Cast iron,copper,PVC,aluminium,FRP etc.(liner allowed) |
Internal Diameter | 50~6000mm | |
Straight Length | Upstream 10D,downstream 5D,30D away from the pump outlet(D for diameter) | |
Medium | Fluid | Water,sea water,acid liquid,beer,alcohol,oil and any other liquid that can spread sonic |
Temperature | -40℃~160 ℃ | |
Turbidity | 10000 ppm and with little bubbles | |
Velocity | 0~ ±12 m/s | |
Operating Environment |
Temperature | Transmitter:-20~60 ℃;Transducer:-40~160 ℃ |
Humidity | Transmitter:85%RH;transmitter protection grade:IP68;Water depth<2m (glued) | |
Power Supply | DC8-36V or AC85-264V | |
Consumption | 1.5W |