Precession vortex flow meter
- Body:Standard:Aluminum alloy Option:SS304,SS316
- Output:4-20mA
- Communication:RS485 MODBUS RTU
- Accuracy:1.0%
- Connect:Flange:DIN,JIS,ANSI
Display parameters can switch freely, can display instantaneous flow (Nm3/h), total flow(Nm3), medium temperature (℃)and pressure (Kpa) at the same screen.
Lower power consumption, could use the battery powered and connect the external power,too.
Double flow sensor, enjoy excellent stability, high accuracy and anti-vibration performance
Can be divided into five sections for correction, this operation will make measuring more accurate
Precession vortex flow meter combines the swirl generator and swirl eliminator in the flow sensor, which can reduce the pressure loss, realize wider flow measuring range, upgrade measurement !
Precession Vortex Flow Meter Main Technical Parameters | ||||||||
Caliber (mm) |
20 | 25 | 32 | 50 | 80 | 100 | 150 | 200 |
Flow Range (m3/h) |
1.2~15 | 2.5~30 | 4.5~60 | 10~150 | 28~400 | 50~800 | 150~2250 | 360~3600 |
Accuracy |
1.0~1.5% | |||||||
Repeatability |
Less than 1/3 of basic error absolute value |
|||||||
Working Pressure (MPa) |
1.6Mpa, 2.5Mpa, 4.0Mpa, 6.3Mpa Special pressure please double check |
|||||||
Application Condition |
Environment temperature: -30℃~+65℃ Relative humidity: 5%~95% Medium temperature: -20℃~+80℃ Atmospheric pressure: 86KPa~106KPa |
|||||||
Working Power |
24VDC+3.6V battery power, can remove the battery | |||||||
Output Signal | 4-20mA, pulse, RS485, alarm | |||||||
Applicable Medium | All gases (except steam) | |||||||
Explosion-proof Mark | Ex ia II C T6 Ga |
Pressure Loss Curve
Installation Dimension Drawing
Caliber (mm) |
Length (mm) |
PN1.6~4.0MPa |
|||||||||||||||||
H | Dφ | Kφ | N | L | dφ | H | Dφ | Kφ | N | L | dφ | H | Dφ | Kφ | N | L | dφ | ||
25 | 200 | 305 | 115 | 85 | 4 | 14 | 65 | ||||||||||||
32 | 200 | 320 | 140 | 100 | 4 | 18 | 76 | ||||||||||||
50 | 230 | 330 | 165 | 125 | 4 | 18 | 99 | ||||||||||||
80 | 330 | 360 | 200 | 160 | 8 | 18 | 132 | ||||||||||||
PN1.6MPa | (Special requirements) PN2.5~4.0MPa | ||||||||||||||||||
100 | 410 | 376 | 220 | 180 | 8 | 18 | 156 | 390 | 235 | 190 | 8 | 22 | 156 | ||||||
150 | 570 | 430 | 285 | 240 | 8 | 22 | 211 | 450 | 300 | 250 | 8 | 26 | 211 | ||||||
PN1.6MPa | PN2.5MPa |
(Special requirements) PN4.0MPa |
|||||||||||||||||
200 | 700 | 470 | 340 | 295 | 12 | 22 | 266 | 490 | 360 | 310 | 12 | 26 | 274 | 510 | 375 | 320 | 12 | 30 | 284 |
Adopt the gas venturi sonic nozzle calibration device and submit the equipment for inspection and verification regularly, which could guarantee the accuracy more stable and reliable !