Male Thread Digital Display Vertical Metal Tube Rotameter

  • Range ratio: :10:1(Special type 20:1)
  • Accuracy class: :2.5(Special type 1.5% or 1.0%)
  • Working pressure: :DN15~DN50 PN16 (Special type 2.5MPa)
  • Medium temperature::Normalized type -80℃~+220℃
  • Ambient temperature::-40℃~+120℃(Remote display without LCD≤85℃)
Share With:
  • Overview
  • Technical Data
  • Inquiry
 

Introduction

The metal tube ratometer flowmeter is a kind of variable area flow quantity measuring instrument. It has such features as small volume, large detection range and convenient operation. It is especially suitable to measure flow quantity of media with small flow velocity and small flow quantity.Intelligentized metal tube rotameters have field indication type and intelligentized remote transmission type. So it provides the customers with very wide selection spaces. In addition, advanced 16 bits micro processor and high quality industrialized components are adopted in the instrument, which ensures excellent performances of the flowmeter in various kinds of application situations.

Advantages

Male Thread Digital Display Vertical Metal Tube Rotameter advantages:

Double indication system

Separation of magnetic coupling and magnetic signals

Double line liquid crystal digital display

Bore diameter of the measuring tube of the flowmeter is complete

Resistance to high temperature and high pressure

Good protection and explosion proofing performance

Full series of installation pattern

Various kinds of power supply patterns

Highly integrated circuit

Systematical software function and standard Hart communication pattern    

 


Application

Male Thread Digital Display Vertical Metal Tube Rotameter Applications

The metal tube rotameter adopts 304/316 stainless steel structure, which can be used to measure the flow of liquid, gas, and steam. It is especially suitable for flow measurement of low flow rate, micro flow range, high temperature, high pressure, corrosive, conductive or non-conductive medium. it widely used in petroleum 、chemical、 food 、water treatment and other industries.


Installation

 

Metal tube rotameter installation

Installed flowmeter should guarantee the entry ≥5DN straight pipe section, export straight pipe section not less than 250mm; if the medium containing ferromagnetic material, magnetic filter should be installed in front of the flowmeter. (see magnetic  filter  and straight pipe section diamension diagram )

 

1.For flow meter installed,ensure the measuring pipe perpendicularity is better than 5 and should be equipped with bypass,easy to maintain and clean and does not affect production..

2.Monitoring and control system in the control valve,should be installed downstream of the flowmeter.For gas measurement,Should ensure the working pressure is not less than 5 times of pressure loss of the flowmeter, to make stable work of the flowmeter.

3.Before install the flowmeter,The pipe should be welding slag purging clean;When installation to remove locking component in the flow meter;when used after installation,Slowly open the control valve,Avoid shock damage  flow meter


 

Table 1: Vertical Display Variable Area Flowmeter Data Sheet

Measuring range

 Water (20℃)                  16~150000 l/h.

 Air(0.1013MPa 20℃)       0.5~4000 m3/h.

 Range ratio  10:1(Special type 20:1).
 Accuracy class  2.5(Special type 1.5% or 1.0%).
 Working pressure

 DN15~DN50 PN16 (Special type 2.5MPa).

 DN80~DN150 PN10 (Special type 1.6MPa).

 Pressure rating of jacket 1.6MPa.

 Medium temperature

 Normalized type -80℃~+220℃.

 High-temperature type 300℃.    Lined with FEP type ≤85℃.

 Ambient temperature

 -40℃~+120℃(Remote display without LCD≤85℃).

 (Remote display with LCD≤70℃).

 Dielectric viscosity

 1/4” NPT, 3/8” NPT 1/2” NPT≤5mPa.s

 3/4” NPT,1” NPT ≤250mPa.s

 Output

 Standard signal: two-wire system 4 ~ 20mA (with HART communication).

 Standard signal: three-wire system 0 ~ 10mA.

 Alarm signal:1.Two-way relay output.

                    2.One-way or two-approach switches .

 Pulse signal output: 0-1KHz isolated output.

 Process connection

 Standard type:24VDC±20%.

 AC type:220VAC(85~265VAC) (optional).

 Connection mode

 Flange

 Thread

 Tri-clamp

 Levels of protection

 IP65/IP67.

 Ex-mark

 Intrinsically safe:ExiaIICT3~6.    Exd type:ExdIICT4~6.

Table 2: Vertical Display Variable Area Flowmeter Flow Range

Caliber

(mm)

Work number Flow range Pressure loss kpa

Water L/h 

Air m3/h Water Kpa Air
Normal type Anti-corrossion type Normal type
Anti-corrossion type

Normal type

Anti-corrossion type
15 1A 2.5~25 -- 0.07~0.7 6.5 - 7.1
1B 4.0~40 2.5~25 0.11~1.1 6.5 5.5 7.2
1C 6.3~63 4.0~40 0.18~1.8 6.6 5.5 7.3
1D 10~100 6.3~63 0.28~2.8 6.6 5.6 7.5
1E 16~160 10~100 0.48~4.8 6.8 5.6 8.0
1F 25~250 16~160 0.7~7.0 7.0 5.8 10.8
1G 40~400 25~250 1.0~10 8.6 6.1 10.0
1H 63~630 40~400 1.6~16 11.1 7.3 14.0
25 2A 100~1000 63~630 3~30 7.0 5.9  7.7
2B 160~1600 100~1000 4.5~45 8.0 6.0 8.8
2C 250~2500 160~1600 7~70 10.8 6.8 12.0
2D 400~4000 250~2500 11~110 15.8 9.2 19.0
40 4A 500~5000 300~3000 12~120 10.8 8.6 9.8
4B 600~6000 350~3500 16~160 12.6 10.4 16.5
50 5A 630~6300 400~4000 18~180 8.1 6.8 8.6
5B 1000~10000 630~6300 25~250 11.0 9.4 10.4
5C 1600~16000 1000~10000 40~400 17.0 14.5 15.5
80 8A 2500~25000 1600~16000 60~600 8.1 6.9 12.9
8B 4000~40000 2500~25000 80~800 9.5 8.0 18.5
100 10A 6300~63000 4000~40000 100~1000 15.0 8.5 19.2
150 15A 20000~100000 -- 600~3000 19.2 -- 20.3

Table 3: Vertical Display Variable Area Flowmeter Model Selection

QTLZ X X X X X X X X X
Indicator Code                
Local indicator Z
LCD indicator with ouput D
Norminal diameter Code
DN15 -15
DN20 -20
DN25 -25
DN40 -40
DN50 -50
DN80 -80
DN100 -100
DN150 -150
Structure Code
Bottom-top /
Left-right (horizontal) H1
Right-left (horizontal) H2
Side-side AA
Bottom -side LA
Thread connection S
Tri-clamp M
Body material Code
304SS R4
316LSS R6L
Hastelloy C Hc4
Titanium Ti
Liner F46(PTFE) F
Monel M
Indicator type Code
Iinear indicator(pointer indication) M7
Nonlinear indicator(LCD Display) M9
Combination function(only for LCD display) Code
24VDC with 4~20mA output S
24VDC with HART communication Z
Battery power D
Additional function Code
Measuring tube with thermal preservation / heat insulation jacket T
Measure medium temperature higher than 120.C HT
Ex-proof: Code
With W
Without N
Alarm Code
One alarm K1
Two alarm K2
None N