• [alt2]

ultrasonic liquid level transmitters manual

  • Measuring Range:4-30m
  • Output Currency:4-20 mA
  • Protection:IP67
  • Sensor Material:ABS,PVC,PTFE
  • Temperature:-40℃~75℃
Share With:
  • Overview
  • Technical Data
  • Inquiry

 

Principle
The sensor of the meter pulses in the direction of the product surface. There, they are reflected back and received by the sensor.The meter measures the time t between pulse transmission and reception. The meter uses the time t (and the velocity of sound) to calculate the distance D between the sensor membrane and the product surface:
D = c •t/2. As the device knows the empty distance H from a user entry, it can calculate the level as follows: L= H – D.
The ultrasonic velocity in gas is influenced by the gas temperature,So the level meter need to detect the gas temperature at work. So the material level meter need to detect the gas temperature at work,compensation for sound velocity.
Blanking distance: Span F may not extend into the blanking distance B. Level echo from the blanking distance cannot be evaluated due to the transient characteristics of the sensor.
                                                                                       
                                                                                B:Blanking distance D:distance value  L:level value    
                                                                                             H: installation height F:level span
 

 

Application
To ensure that the ultrasonic transmission to the measured ultrasonic liquid level or material surface occasion.
Such as: storage tank, chute, pool, Wells, drains, metering box, granary etc.


Features
♦  Integrated design, installed conveniently
♦  Protected in the excessive voltage and current , protected in the thunder and lightning
♦  The big show window of LCD is easy to debug and observe
♦  Over-voltage over-current protection, lightning protection
♦  Advanced since the clamp type terminal, to ensure that wiring never loose
♦  Intellectual signal treatment technology, guarantee that the instrument meets various kinds of operating occasion
♦  All plastic probe, acid and alkali resistant, adapt to bad environment
 
Range
The instrument has the following range specifications: Liquid level: 4m,6m,8m,12m,20m,30m;
Material level: 3m,5m,7m,10m,15m;
 
Note
♦  The above range level measurement only,Material level measuring the effective range of about 50% of the data,material level measuring proposal chooses four wire or split type level gauge.
♦  Cold area outdoor installing applications, should prevent the probe surface frost or freeze.Can choose pipe long material level meter, the internal probe into the container,above model and models.
                   

                    4m, 6m, 8m                                                       12m, 20m, 30m                                                                 20m, 30m horn type




 
certificate






                     

                         Ultrasonic Level Meter Specifications

Power supply

DC24V (±10%) 30mA

Display

4 digit LCD

Display resolution

0.03% of the actual range

Output current

4-20mA

Output load

0-500Ω

Temperature range

-40 ℃~75℃

Pressure range

±0.1MPa (press definitely)

Temperature compensation

full range of automatic compensation

Cable diameter

Φ 6 ~ Φ12 mm

Single wire diameter

Φ0.5 ~ Φ1.78 mm

Measuring Cycle

1.5 seconds

8º(3db) for range

Plane Type Sensor (4m 6m 8m 12m 20m 30m)

5º(3db) for range

Horn Type Sensor (20m,30m)

Electronic unit shell material

die-casting aluminum with plastic-sprayed surface

The sensor material

ABS/PVC/PTFE

Protect grade

IP67