• [alt2]
  • circle
  • convertor
  • electrode
  • tri-clamp

Beverage Flow Meter

  • Electrode:SS316L,HC,HB,Tan,Ti,Pt
  • Liner Material:PTFE,PFA,FEP,F46,Neoprene,Rubber
  • Accuracy:0.5% or 0.2%
  • Output Mode:4~20 mA,pulse
  • Medium Temperature:-10℃~180℃
Share With:
  • Overview
  • Technical Data
  • Inquiry
Principle
Beverage flow meter works based on Faraday's Law and measure conductive medium with conductivity more than 5 μs/cm and flow range from 0.2 to 15 m/s.
 

Application
According customers requirements,we can provide diversified electromagnetic flowmeters widely used following industries,
     • Chemical
      Medicine
     • Beverage
     • Iron and steel
      Water supply
     • Electricpower
      Water treatment
 

Features
      No moving parts,no pressure loss
     Accuracy:±0.2% of the measured value + 0.3m/s 
     • High accuracy for low flor rate and can measure duplex flow
      Double frequency excitation,stable zero point 
     •Built-in ground electrode,no need grounding ring

sanitary flow meter




 
 


 
certificate






Sanitary Magnetic Flow Meter Specification

Size

DN3~DN200mm

Accuracy

±0.5% of reading,velocity >0.3 m/s  

Conductivity

Normal liquid >5 μS/cm,DI water >20 μS/cm      

Velocity

0.1 ~ 15 m/s

Structure type

Integrated, Seperated

Liner Material

PFA    DN3-DN800   (standard)    -20 ~ +120      -68~ 248℉)
PTFE   DN15-DN1600    -20 ~ +120      -68~ 248℉)
F46     DN25-DN1800     -20 ~ +120     -68~ 248℉)

Electrode Material

SS 316L (standard),Hastelloy C,Hastelloy B

Body Material

Stainless Steel 304 (standard),stainless steel 316L

Process Pressure

0.6 MPa, 1.6 MPa

Frequency Output     

1~5000 Hz

Signal Output

4~20 mA,pulse

Communication

RS485/Modbus,Hart over 4~20 mA, Hart,Profitbus

Power Supply

AC85~250V, DC20V~36V       

Ambient Temperature

-25 ~ +60  /-77 ~ 140 Sensor      -10~ +60 /-50~140 Convertor

Liquid Temperature

Integrated: 70/ 158 max    Seperated: 120/ 248max

Protection Grade

IP65 Integrated,  IP68 Seperated

Connection

Thread,Tri-clamp

Exciting Current    

125mA, 187mA, 250mA, 500mA

Exciting Frequency   

25Hz, 3.125Hz, 2.5Hz, 2Hz

Straight Pipe     

Inlet Path ≥ 10D,  Outlet Path ≥ 5D

Certificates        

CE 6022120716, ISO9001:2008, CQC1500155689521




Sanitary Magnetic Flow Meter Selection Table




Performance of Electrodes

Electrode Material

Applications

Stainless Steel 316L

Applicable in water,sewage and corrosive mediums.Widely used in industries of petrol,chemistry,carbamide,etc

Hastelloy B (HB)

Having strong resistance to hydrochloric acid of any consistance which  is below bioling piont.
Also resistable against vitriol,phosphate,hydrofluoricacid,organic acid etc which are oxidable acid,alkali and non-oxidable salt.

Hastelloy C (HC)

Be resistant to oxidable acid such as nitric acid,mixed acid,as well as oxidable salt such as Fe+++,Cu++aStnd sea water

Titanium

Applicable in seawater,and kinds of chloride,hypochlorite salt,oxidable acid (including fuming nitric acid),organic acid,alkali etc.
Not resistant to a pure reducing acid(such as sulphuric acid,hydrochloric acid  corrosion.
But if acid contains antioxidant is greatly reduce corrosion.

Tantalum

Having strong resistance to corrosive mediums that is similar with glass
Almost is applicable to all chemical mediums.
Except for hydrofluoric acid,oleum and alkali.

Platinum-iridium

Almost be applicable in all chemical mediums except for ammonium salt.

Stainless Steel Covered
Tungsten Carbide

Applicable in mediums of no corrosive and low abrasion.

 

 

Inquiry >>