Turbine flowmeter

2021-08-31
 Turbine flowmeter 
The gas is used to push the impeller of the flow meter to rotate. 

The speed of the impeller is proportional to the volume flow of the fluid.
According to the principle of electromagnetic induction, 
a magnetic sensor is used to sense a pulse signal proportional to 
the volume flow of the fluid from the synchronously rotating impeller.
The volume flow is calculated. The measurement accuracy is high, 
and the accuracy grade can reach 1.0 and 1.5.
Wide range ratio, the general measurement range is 1:20; compact and lightweight structure, 
convenient installation and maintenance, 
low requirements for front and rear straight pipe sections, 
can be used for medium and high pressure measurement.



 

share:

Pre:Electromagnetic Flowmeters
Next: LWGY Turbine Flowmeter Fault Analysis