Gas turbine flow meter oiling method and period

2020-04-08
 Gas turbine flow meter oiling method and period

Gas turbine flow meter refueling method: press down the manual lever of the oil pump by hand until it stops, so that the same oil pressure can be formed every time. Pressing the manual lever down once means one stroke of the oil pump piston.

Gas turbine flow meter refueling cycle: fill the turbine flow meter with special turbine oil every 1 month to 3 months. Refueling once a month, such as the urban pipe network, where the pressure is relatively low, refueling once every 3 months.

Gas turbine flow meter refueling capacity: 4 strokes / each time. Each substation should refuel strictly according to the refueling cycle and refueling volume of the turbine flow meter, and fill the results into the technical file of the turbine flow meter.

The oil pump must be isolated from water (note whether the stickers or screws on the cover of the oil filler hole are tightly tightened).

Check the turbine flow meter, thermometer, and pressure gauge every 2 hours, monitor the flow meter for noise, check the meter counter for card counts, discontinuous records, etc. If you find an abnormality, please immediately consult and switch the flow meter.



share:

Pre:New arrival Multi-channel ultrasonic flow meter
Next:Sonic nozzle ship