Introduction of Electromagnetic Flow meter's Electrode Materials

2020-03-13
 Introduction of Electromagnetic Flow meter's Electrode Materials
 
Stainless steel 316L: suitable for water, sewage and general corrosive media.
 
Hastelloy B: Has good corrosion resistance to non-oxidizing acids, alkalis and salt solutions.
 
Hastelloy C: Has good corrosion resistance to oxidizing acids, alkalis and salt solutions.
 
Tantalum: expensive, except for hydrofluoric acid, it is suitable for almost all kinds of corrosive media.
 
Zirconium: special needs.
 
Titanium: suitable for seawater, various chlorides and hydroxides.